Preparing for Use
If the stapler has been stored in a cold environment, bring it to a warm area and allow it to warm
up before using.
Loading
- Make sure stapler is disconnected from air supply.
- Only use the proper size and type of staple with this stapler, as specified under "Staples".
- Depress the track release lever to release the spring-loaded staple magazine; slide the magazine
out (back) as far as it will go.
- Turn the stapler upside down. Place a full strip of staples into the staple magazine, with the
staple points facing upward (away from the tool). Slide the staple magazine closed until the
track release lever snaps back into place with a click. (Closing the staple magazine while
staples are loaded engages the spring-load mechanism, so it will take slightly more pressure to
slide the magazine closed.)
Using the Stapler
- This stapler is equipped with a contact safety mechanism; the trigger will not operate unless the
contact mechanism is firmly depressed against the surface to be stapled.
- Grip the body of the stapler firmly, make sure that the contact mechanism is placed securely
against work surface, and pull the trigger to drive a staple.
- Remove finger from the trigger.
- To drive another staple, move the stapler to next area on work surface to be stapled, and repeat
these steps.
After Stapling
- Disconnect the air hose from the stapler.
- Remove all staples from the staple magazine of the stapler.
- Place several drops of oil (included in case) into the air plug.
- Shut off air compressor and drain any moisture from the compressor tank.
- Drain the air line filter; clean the filter element, then blow air in opposite direction to remove any
dirt/debris.
- Keep lubricator filled with oil (included in case).
Clearing Staple Jams
- Disconnect the air hose from the stapler.
- Carefully remove staple strip from staple magazine.
- Remove any remaining loose staples from inside the staple magazine, using pliers to grasp the
staples, if necessary.
- Once jammed staples have been removed, reload stapler.
20
0
40
60
80
100
120
140
160
Lubricator Regulator Filter
To compressor
To Air Tool
Quick Connector Quick Coupler
APPLICATIONS
Including, but not limited to: insulation, roofing felt, house wrap, auto and marine vinyl trim,
cabinet felt, cabinet backs, screen door repair, small furniture, light trim, molding and picture
frames, and general staple use.
FEATURES
- View window for staples
- Adjustable exhaust
- Rubber hand grip for comfort
- Firing Safety mechanism
- Easy drop-in staple loading
OPERATION
The Surebonder 9610 Pneumatic Stapler is designed to use No.6 heavy-duty wide crown
staples in 1/4”, 5/16”, 3/8", 1/2", and 9/16” leg lengths. For best results, use Surebonder Heavy
Duty Staples.
AIR SUPPLY
This stapler is designed to operate on clean, dry, regulated compressed air, between 60 and
100 psi. It is preferable to include an air filter, pressure regulator, and automatic oiler within 15
feet of the tool, if possible.
An air filter is needed to remove contaminates and moisture that are contained in compressed
air; filtering will significantly prolong the life of the tool. If an automatic oiler is not installed,
place 5 to 6 drops of oil into the tool's air inlet at the beginning of each work day.
The staple gun comes factory-equipped with a male quick connector. The staple gun must
always be connected to the air supply with a coupling that removes all pressure when it is
disconnected.
NOTE: all components used with this staple gun (air hose, connectors, regulators,
filters, etc) must be rated at 120 psi, OR 120% of the maximum compressor
potential, whichever is higher. Do not connect this staple gun to a system with
maximum potential air pressure greater than 200 psi.